- Access by Xinjiang University
Application of superconducting quantum interference devices to nuclear magnetic resonance
Rev. Mod. Phys. 70, 175 – Published 1 January, 1998Erratum Rev. Mod. Phys. 72, 329 (2000)
DOI: https://doi.org/10.1103/RevModPhys.70.175
Abstract
Nuclear magnetic resonance (NMR) provides information in low polarizing fields that is hard to obtain in high fields. A new generation of sensitive NMR detectors, the superconducting quantum interference device (SQUID), provides a fresh approach to low-field NMR studies. The SQUID is an ideal detector for low-field NMR, since its response does not depend on signal frequency as is the case of conventional NMR spectrometers. This review describes the experimental and theoretical studies in which SQUIDs have been used for the detection of NMR. Particular attention is paid to the calculation of the signal-to-noise ratio of SQUID NMR spectrometers with various input configurations as compared to that of conventional ones. The application of SQUIDs to nuclear thermometry and to absolute field measurements are also discussed. A SQUID directly measures the longitudinal nuclear magnetization and the review discusses extensively what we call spectroscopy.
Erratum
References (179)
- Abragam, A., 1961, The Principles of Nuclear Magnetism (Clarendon, Oxford).
- Adams, R., S. P. Potts, J. C. Gallop, and W. J. Radcliffe, 1980, “Applications of SQUID to Nuclear Gyro and Magnetometers,” in SQUID’80, Proceedings of the 2nd International Conference on SQUID Devices and their Applications, Berlin, edited by H. D. Hahlbohm and H. Lubbig (Walter de Gruyter, Berlin/New York), pp. 509–517.
- Ahola, H., G. E. Ehnholm, S. I. Islander, P. Ostman, and B. Rantala, 1980, “Tin, a candidate for low temperature NMR thermometer,” Cryogenics 5, 277–282.
- Ahola, H., G. E. Ehnholm, S. I. Islander, and B. Rantala, 1978, “Nuclear Spin Lattice Relaxation Time in Tin,” J. Phys. C 6, 1215–1216.
- Anderson, A.G., 1959, “Nonresonant Nuclear Spin Absorption in Lithium, Sodium, and Aluminum,” Phys. Rev. 115, 863–868.
- Anderson, A. G., 1962, “Nuclear Spin Absorption Spectra in Solids,” Phys. Rev. 125, 1517–1527.
- Anderson, A. G., and S. R. Hartmann, 1962, “Nuclear Magnetic Resonance in the Demagnetized State,” Phys. Rev. 128, 2023–2041.
- Babcock, J., J. Kiely, T. Manley, and W. Weyhmann, 1979, “Nuclear susceptibility thermometry using enriched ” Rev. Sci. Instrum. 50, 1310–1312.
- Barone, A., and G. Paterno, 1982, Physics and Application of the Josephson Effect (Wiley, New York).
- Bene, G. J., 1980, “Nuclear Magnetism of Liquid Systems in the Earth Field Range,” Phys. Rep. 58, 213–267.
- Bene, G. J., 1988a, “NMR in the low and very low magnetic field range,” in Proceedings of the 10th Ampere Summer School and Symposium “Magnetic Resonance and Relaxation: New fields and Techniques,” Portoroz, edited by R. Bline, M. Vilfan, and J. Slak (J. Stefan Institute, Ljubljana).
- Bene, G. I., 1988b, “Identification des milieux riches en eau par la relaxation magnetique des protons,” Rev. Rom. Phys. 33, 381–392.
- Bergmann, W. H., 1981, “Proposals for an improvement of NMR imaging by low temperature SQUID detection towards molecular kinetic measurements localized to a small sub-region of the sample,” in Biomagnetism, Proceedings of the 3rd International Workshop on Biomagnetism, Berlin, 1980, edited by S. N. Erné, H. D. Hahlbohm, and H. Lübbig (W. de Gruyter, Berlin), pp. 535–548.
- Bergmann, W. H., 1983, “A new approach to NMR flow imaging and analysis,” in Nuclear Magnetic Resonance Imaging, edited by E. L. Pertain, A. E. James, et al. (W. B. Sanders, City), pp. 487–493.
- Bielecki, A., J. B. Murdoch, D. D. Weitenkamp, D. B. Zax, K. W. Zilm, H. Zimmerman, and A. Pines, 1984, “Fourier transform pure nuclear quadrupole resonance by pulsed field cycling,” J. Chem. Phys. 80, 2232–2234.
- Bielecki, A., D. B. Zax, K. W. Zilm, and A. Pines, 1986, “Zero field NMR and NQR Spectrometer,” Rev. Sci. Instrum. 57, 393–403.
- Bishop, J. H., E. C. Hirschkoff, and J. C. Wheatley, 1971, “Very Low Temperature Static Magnetic Properties of Certain Metals Possibly Useful as Magnetic Thermometers,” J. Low Temp. Phys. 5, 607–616.
- Black, B., G. Majer, and A. Pines, 1993, “SQUID NMR study of methyl quantum tunneling in a series of carboxylic acids,” Chem. Phys. Lett. 201, 550–554.
- Bloch, F., 1946, “Nuclear Induction,” Phys. Rev. 70, 460–473.
- Bloembergen, N., S. Shapiro, P. S. Pershan, and J. O. Artman, 1959, “Cross-Relaxation in Spin Systems,” Phys. Rev. 114, 445–459.
- Borodin, M. P., A. V. Mel’nikov, A. A. Morozov, and Yu. S. Chernyshev, 1967, “Nuclear Magnetic Resonance in the Earth Field” (Leningrad State University, in Russian).
- Bourgeois, B. S., J. H. Ross, and W. Avera, 1991, “High accuracy magnetic measurements with the ASQ-81 scalar magnetometer,” IEEE Trans. Instrum. Meas. 40, 784–787.
- Chamberlin, R. V., L. A. Moberly, and O. G. Symko, 1979, “High sensitivity magnetic resonance by SQUID detection,” J. Low Temp. Phys. 35, 337–347.
- Chang, J., C. Connor, E. L. Hahn, H. Huber, and A. Pines, 1989, “Direct detection of Resonance with a SQUID spectrometer,” J. Magn. Reson. 82, 387–391.
- Clarke, J., 1989, “SQUID Concepts and Systems,” in Superconducing Electronics, NATO ASI Series No. 59, edited by H. Weinstock and M. Nisenoff (Springer, Berlin/Heidelberg), pp. 87–148.
- Clarke, J., 1993, “SQUIDs: Theory and Practice,” in The New Superconducting Electronics, edited by H. Weinstock and R. W. Ralston (Kluwer Academic, Dordrecht), pp. 123–180.
- Clarke, J., 1994, “Low Frequency NQR with SQUID Amplifier,” Z. Naturforsch. Teil A 49A, 5–13.
- Clarke, J., W. M. Goubau, and M. B. Ketchen, 1976, “Tunnel Junction DC SQUID: Fabrication, Operation and Performance,” J. Low Temp. Phys. 25, 99–144.
- Clarke, J., C. D. Tesche, and R. P. Giffard, 1979, “Optimization of DC SQUID Voltmeter and Magnetometer Circuits,” J. Low Temp. Phys. 37, 405–420.
- Connor, C., 1990, “Low Frequency Magnetic Resonance with a DC SQUID,” in Adv. Magn. Opt. Res., edited by W. S. Warren (Academic, City), vol. 15, pp. 201–263.
- Connor, C., J. Chang, and A. Pines, 1990a, “Magnetic resonance spectrometer with a DC SQUID detector,” Rev. Sci. Instrum. 61, 1059–1063.
- Connor, C., J. Chang, and A. Pines, 1990b, “Aluminum and boron nuclear quadrupole resonance with a DC SQUID,” J. Chem. Phys. 93, 7639–7646.
- Cukauskas, E. J., D. A. Vincent, and B. S. Deaver, Jr., 1974, “Magnetic susceptibility Measurements using a Superconducting Magnetometer,” Rev. Sci. Instrum. 45, 1–6.
- Day, E. P., 1972a, “Detection of NMR using a Josephson Junction Magnetometer,” Phys. Rev. Lett. 29, 540–542.
- Day, E. P., 1972b, “Static susceptibility of biological molecules and SQUID detection of NMR,” in Proceedings of the 13th International Conference on Low Temperature Physics (publisher, city), Vol. 4, pp. 550–554.
- Deaver, B. S., Jr., T. J. Bucelot, and J. J. Finley, 1978, “SQUID for Measuring the Magnetic Properties of Materials,” in Future Trends in Superconductive Electronics, AIP Conf. Proc. No. 44 (AIP, New York, 1978), pp. 58–72.
- Derome, A. T., 1997, Modern NMR technique for chemistry research (Pergamon, New York).
- Donaldson, G. B., 1989, “SQUIDs for Everything Else,” in Superconducting Electronics, NATO ASI Series No. 59, edited by H. Weinstock and M. Nisenoff (Springer, Berlin/Heidelberg), pp. 175–207.
- Drung, D., 1991, “DC SQUID Systems Overview,” Supercond. Sci. Technol. 4, 377–385.
- Drung, D., 1994, “Recent LTS SQUID Developments,” IEEE Trans. Appl. Supercond. 4, 121–127.
- Drung, D., 1996, “Advanced SQUID Readout Electronics,” in SQUID Sensors: Fundamentals, Fabrication and Applications, NATO ASI Series E, No. 329, edited by H. Weinstock (Kluwer Akademic, Dordrecht), in press.
- Drung, D., R. Cantor, M. Peters, H. J. Scheer, and H. Koch, 1990, “Low Noise High Speed DC SQUID Magnetometer with Simplified Feedback Electronics,” Appl. Phys. Lett. 57, 406–408.
- Drung, D., R. Cantor, M. Peters, T. Ryhanen, and H. Koch, 1991, IEEE Trans. Magn. MAG-27, 3001.
- Drung, D., H. Matz, and H. Koch, 1995, “A 5 MHz Bandwidth Magnetometer with additional Positive Feedback,” Rev. Sci. Instrum. 66, 3008–3015.
- Ehnholm, G. J., J. P. Eckstrom, M. T. Loponen, and J. K. Soini, 1979a, “Transversal SQUID NMR,” Cryogenics 19, 673–678.
- Ehnholm, G. J., J. P. Eckstrom, J. F. Jacquinot, M. T. Loponen, O. V. Lounasmaa, and J. K. Soini, 1979b, “Evidence for Nuclear Antiferromagnetism in Copper,” Phys. Rev. Lett. 42, 1702–1705.
- Ehnholm, G. J., J. P. Eckstrom, J. F. Jacquinot, M. T. Loponen, O. V. Lounasmaa, J. K. Soini, 1980, “NMR studies on nuclear ordering in metallic copper below 1 mK,” J. Low Temp. Phys. 39, 417–450.
- Ekström, J. P., J. F. Jacquinot, M. T. Loponen, J. K. Soini, and P. Kumer, 1979, “Nuclear spin interaction in copper: NMR at high polarization and in low fields,” Physica B 98, 45–52.
- Fan, N. Q., M. B. Heaney, J. Clarke, D. Newitt, L. L. Wald, E. L. Hahn, A. Bielecki, and A. Pines, 1989, “Nuclear Magnetic Resonance with DC SQUID preamplifier,” IEEE Trans. Magn. 25, 1193–1199.
- Fan, N. Q., M. D. Hürlimann, J. Clarke, A. Pines, and E. L. Hahn, 1990, “Fourier Transform Zero Field NMR and NQR with a DC SQUID,” Bull. Am. Phys. Soc. 35, 645.
- Fan, N. Q., and J. Clarke, 1991, “Low Frequency NMR and NQR spectrometer based on DC SQUID,” Rev. Sci. Instrum. 62, 1453–1459.
- Foglietti, W., W. J. Gallagher, M. B. Ketchen, A. W. Kleisasser, R. H. Koch, S. I. Raider, and R. L. Sandstrom, 1986, “Low Frequency Noise in Low Noise DC SQUIDs,” Appl. Phys. Lett. 49, 393–1395.
- Freeman, M. R., R. S. Germain, and R. C. Richardson, 1986, “Low temperature nuclear magnetic resonance with a DC SQUID preamplifier,” Appl. Phys. Lett. 48, 300–302.
- Freeman, M. R., M. L. Roukes, R. S. Germain, and R. C. Richardson, 1984, “DC SQUID small signal amplifiers for NMR,” in Proceedings of the 17th International Conference on Low Temperatures, edited by U. Eckern, A. Schmid, W. Weber, and H. Wuhl (Elsevier Science, New York/Amsterdam), Part I, pp. 267–268.
- Friedman, L. J., A. K. M. Wennberg, S. N. Ytterboe, and H. M. Bozler, 1986a, “Direct Detection of Low Frequency NMR using a DC SQUID,” Rev. Sci. Instrum. 57, 410–413.
- Friedman, L. J., S. N. Ytterboe, H. M. Bozler, A. L. Thomson, C. Cross, 1986b, “Detection of Ferromagnetic Domains in a Two-Dimensional Nuclear Spin System,” Phys. Rev. Lett. 57, 2943–2946.
- Friedman, L. J., A. L. Thomson, C. M. Gould, H. M. Bozler, P. B. Weichman, and C. Cross, 1989, “Zero-Field Magnetic Order in the Boundary Layers of on Grafoil,” Phys. Rev. Lett. 62, 1635–1638.
- Fujii, I., A. I. Kushima, and Y. Yoshida, 1980, “An Estimate of the signal-to-noise ratio in NMR measurements at ultra low Temperatures,” Jpn. J. Appl. Phys. 19, 977–984.
- Gallap, J. C., and W. J. Radcliffe, 1978, “Cryogenic free precession He Magnetometer using a SQUID,” J. Phys. D 11, L203–L206.
- Gallop, J. C., and W. J. Radcliffe, 1981, “The He-SQUID magnetometer: performance limit and applications,” Physica B 107, 621–622.
- Gallop, J. C., and W. J. Radcliffe, 1985, “An absolute SQUID magnetometer,” IEEE Trans. Magn. MAG-21, 602–605.
- Giffard, R. P., 1980, “Fundamentals for SQUID Applications,” in SQUID ’80, Proceedings of the 2nd International Conference on SQUID Devices and their Applications, Berlin, edited by H. D. Hahlbohm and H. Lubbig (Walter de Gruyter, Berlin/New York), pp. 445–471.
- Goldman, M., 1970, Spin Temperature and NMR in Solids (Clarendon, Oxford/London).
- Goldman, M., 1991, Quantum Description of High Resolution NMR in Liquids (Oxford University Press, New York).
- Greenberg, Ya. S., 1993, “Self-Consistent Theory of a Voltage-Current Characteristic and of Intrinsic Noise of Hysteretic RF SQUID,” J. Low Temp. Phys. 92, 367–413.
- Gudoshnikov, S. A., A. N. Kozlov, Yu. V. Maslennikov, A. Yu. Serebrlakov, and O. V. Snigirev, 1991, “Direct measurement of the magnetic field induced by optically polarized -atoms,” IEEE Trans. Magn. MAG-27, 2449–2451.
- Hahn, E., 1950, “Spin Echoes,” Phys. Rev. 80, 580–594.
- Hakonen, P. J., K. K. Nummila, R. T. Vuorinen, and S. Yin, 1992, “Antiferromagnetic Ordering in Silver at Picokelvin Temperatures,” J. Magn. Magn. Mater. 104-107, 903–904.
- Hakonen, P. J., and R. T. Vuorinen, 1992, “Nuclear Ferromagnetic Ordering in Silver at Negative Nanokelvin Temperatures,” J. Low Temp. Phys. 89, 177–186.
- Hakonen, P. J., and S. Yin, 1991, “Investigation of Nuclear Magnetism in Silver down to Picokelvin Temperatures, II,” J. Low Temp. Phys. 85, 25–65.
- Hennel, J. W., A. Birczynski, S. F. Sagnowski, and M. Stahurova, 1984, “Zero field NMR. Calculation of Spectra,” Z. Phys. B 56, 133–138.
- Hilbert, C., and J. Clarke, 1985a, “Application of DC SQUID to RF amplification in NQR,” in SQUID ’85, Proceedings of the 3rd International Conference on SQUID Devices and their Applications, Berlin, edited by H. D. Hahlbohm and H. Lubbit (Walter de Gruyter, Berlin/New York), pp. 829–839.
- Hilbert, C., and J. Clarke, 1985b, “Measurements of the Dynamic Input Impedance of a DC SQUID,” J. Low Temp. Phys. 61, 237–262.
- Hilbert, C., and J. Clarke, 1985c, “DC SQUID as Radiofrequency Amplifier,” J. Low Temp. Phys. 61, 263–280.
- Hilbert, C., J. Clarke, T. Sleator, and E. L. Hahn, 1985, “Nuclear quadrupole resonance detected at 30 MHz with a DC SQUID,” Appl. Phys. Lett. 47, 637–639.
- Hirschkoff, E. C., O. G. Symko, L. L. Vant-Hull, and J. C. Weatley, 1970, “Observation of Static Nuclear Magnetism of Pure Metallic Copper in Low Magnetic Fields,” J. Low Temp. Phys. 2, 653–665.
- Hoult, D. I., and R. E. Richards, 1975, “Critical factors in the design of high resolution NMR spectrometer,” Proc. R. Soc. London, Ser. A 344, 311–340.
- Hoult, D. I., and R. E. Richards, 1976, “The signal to noise ratio of the nuclear magnetic resonance experiment,” J. Magn. Reson. 24, 71–85.
- Hubert, O., Y. Monfort, J. Lepaisant, C. Gunther, and D. Bloyet, 1996, “Amplification by Frequency Transposition with a Low Critical Temperature DC SQUID,” J. Phys. (Paris) 6, 77–90.
- Huiku, M. T., 1984, “Nuclear magnetism in copper at nanokelvin temperatures and in low external magnetic fields,” Physica B 126, 51–61.
- Huiku, M. T., T. A. Jyrkkiö, and M. T. Loponen, 1983, “Experimental Curve of Entropy and Susceptibility versus Temperature for Copper Nuclear Spin Down to the Ordered State,” Phys. Rev. Lett. 50, 1516–1519.
- Huiku, M. T., and M. T. Loponen, 1982, “Observation of a Magnetic Phase Transition in the Nuclear Spin System of Metallic Copper at Nanokelvin Temperatures,” Phys. Rev. Lett. 49, 1288–1291.
- Hürlimann, M. D., C. H. Pennington, N. Q. Fan, J. Clarke, A. Pines, and E. L. Hahn, 1992, “Pulsed Fourier-Transform NQR of with a DC SQUID,” Phys. Rev. Lett. 69, 684–687.
- Jach, T., 1976, “Detection of NQR via induced longitudinal magnetization,” Appl. Phys. Lett. 28, 49–51.
- Jackel, L. D., R. A. Buhrman, 1975, “Noise in RF SQUID,” J. Low Temp. Phys. 19, 201–246.
- Jaglicic, Z., J. Luznik, J. Pirnat, Z. Trontelj, R. Cantor, and D. Drung, 1993, “Application of the DC SQUID for the detection of Nuclear Magnetization,” in Proceedings of the first European Conference on Applied Superconductivity, Göttingen, Germany, edited by H. C. Freyhardt (DGM Informationsgesellschaft, city), Vol. 2, pp. 1645–1648.
- Jardetzky, O., and G. C. K. Roberts, 1981, NMR in Molecular Biology (Academic, New York), pp. i–xiii, 1–681.
- Kakimi, Y., K. Fujioka, and Y. Kuraoka, 1992, “Apparatus for temperature controlled SQUID NMR from 4.2 to 300,” in Advances in Cryogenic Engineering, edited by R. W. Fast (Plenum, New York), Vol. 37, pp. 631–636.
- Koch, H., 1989, “SQUID sensors,” in Sensors: A Comprehensive Survey, Vol. 5, Magnetic Sensors, edited by R. Boll and K. J. Overshott (VCH Verlagsgesellschaft), pp. 381–445.
- Koch, R. H., J. Clarke, W. M. Goubau, J. M. Martinis, C. M. Pegrum, and D. J. Van Harlingen, 1983, “Flicker Noise in Tunnel Junction DC SQUIDs,” J. Low Temp. Phys. 51, 207–224.
- Koch, R. H., J. R. Rozen, P. Woltgens, T. Picunko, W. J. Goss, D. Gambrel, D. Lathrop, R. Wiegert, and D. Overway, 1996, “High Performance Superconducting Quantum Interference Device Feedback Electronics,” Rev. Sci. Instrum. 67, 2968–2976.
- Kohl, M., 1986, “Description of a SQUID NMR Susceptometer,” in Proceedings of the 4th Chech. Symposium on Weak Superconductivity (Electrotecnical Institute, Smolenice), pp. 198–200.
- Kohl, M., M. Odehnal, V. Petricek, and R. Tichy, 1985, “Detection of NMR Larmor and Double Larmor Frequency of Protons by a SQUID,” in SQUID ’85, Proceedings of the 3rd International Conference on SQUID Devices and their Application, Berlin, edited by H. D. Hahlbohm and H. Lubbit (Walter de Gruyter, Berlin/New York), pp. 879–883.
- Kohl, M., M. Odehnal, V. Petricek, R. Tichy, and J. Chalupecky, 1986, “Allowed and forbidden nuclear resonances in low magnetic field measured with a SQUID NMR susceptometer,” in Proceedings of the 4th Chech. Symposium on Weak Superconductivity (Electrotechnical Institute, Smolenice), p. 194.
- Kohl, M., M. Odehnal, V. Petricek, R. Tichy, and S. Safrata, 1988, “Observation of higher order NMR Larmor lines by SQUID in solids at low magnetic field,” J. Low Temp. Phys. 72, 319–343.
- Koike, Y., H. Suzuki, S. Abe, Y. Karaki, M. Kubota, and H. Ishimoto, 1995, “Ferromagnetic Nuclear Spin Ordering of Scandium,” J. Low Temp. Phys. 101, 617–622.
- Koivuniemi, J., Y. Kondo, and M. Krusius, 1996, “DC SQUID Preamplifier for Low Temperature NMR,” Czech. J. Phys. 46, Suppl. S5, 2841–2842.
- Komu, M., 1992, “Methods for Tissue Characterization in Low Field Magnetic Resonance Imaging,” Ph.D. thesis (University of Turku, Turku, Finland).
- Kondo, Y., T. Mizusaki, and A. Hirai, 1989, “Study of Surface Relaxation Mechanism of Liquid He in Porous Glass by using SQUID NMR,” J. Low Temp. Phys. 75, 289–306.
- Konotop, D. A., 1982, “Investigation of Magnetic susceptibility of Zinc using SQUID Technique,” Fiz. Nizk. Temp. 8, 665 [Sov. J. Low Temp. Phys. 8, 333 (1982)].
- Kreis, R., D. Suter, and R. R. Ernst, 1985, “Time Domain Zero Field Magnetic Resonance with Field Pulse Excitation,” Chem. Phys. Lett. 118, 120–124.
- Kubo, R., and T. Toyabe, 1967, “A Stochastic Model for Low Field Resonance and Relaxation” in Magnetic Resonance and Relaxation, edited by R. Blinc (North-Holland, Amsterdam), p. 810.
- Kumar, S., W. F. Avrin, and B. R. Whitecotton, 1996, “NMR of Room Temperature Samples with a Flux-Locked DC SQUID,” IEEE Trans. Magn. 32, 5261–5264.
- Kumar, S., B. D. Thorson, and W. F. Avrin, 1995, “Broadband SQUID NMR with Room Temperature Samples,” J. Magn. Reson., Ser. B 107, 252–259.
- Kurkijarvi, J., 1972, “Intrinsic Fluctuations in a Superconducting Ring Closed with a Josephson Junction,” Phys. Rev. B 6, 832–835.
- Kurkijarvi, J., 1973, “Noise in the Superconducting Quantum Flux Detector,” J. Appl. Phys. 44, 3729–3733.
- Kurkijarvi, J., and W. W. Webb, 1972, “Thermal Fluctuation Noise in a Superconducting Flux Detector,” in Proceedings of the 1972 Applied Superconductivity Conference (IEE, New York), pp. 581–587.
- Kuropjatnik, I. N., Yu. G. Kriger, F. S. Rahmankulov, and A. I. Romanenko, 1984, “The application of superconducting magnetometer to relaxation spectrometry in NMR,” in All Union Conference on Magnetic Resonance in Condensed Matter, Kazan, Russia, Book of abstracts, pt. 3, p. 135.
- Kuropjatnik, I. N., Yu. G. Kriger, F. S. Rahmankulov, A. I. Romanenko, 1987, “The Applica-tion of SQUID Magnetometer to NMR Spectroscopy,” in IXth Ampere Summer School, Sept. 20–26, Novosibirsk, edited by R. Z. Sagdeev (publisher, city), p. 215.
- Leppelmeier, G. W., and E. L. Hahn, 1966, “Nuclear Dipole Field quenching of Integer Spins,” Phys. Rev. 141, 724–731.
- Libove, J. M., and J. R. Singer, 1980, “Resolution and Signal-to-Noise Relationships in NMR Imaging in the Human Body,” J. Phys. E 13, 38–44.
- Lusher, C. P., M. R. Dann, R. P. Reed, M. E. Digby, B. Gowan, J. Saunders, 1996, “Direct Detection of NMR at Low Frequencies Using a DC SQUID amplifier,” Czech. J. Phys. 46, Suppl. S5, 2831–2832.
- Mamiya, T., H. Tsujii, A. Ikeya, and Y. Yasuda, 1995, “Frequency Dependence of AC Susceptibility of bcc Solid ” J. Low Temp. Phys. 101, 689–693.
- Meredith, D. J., G. R. Pickett, and O. G. Symko, 1972, “Detection of NMR at Low Temperatures using a SQUID,” Phys. Lett. 42A, 13–14.
- Meredith, D. J., G. R. Pickett, and O. G. Symko, 1973, “Application of SQUID Magnetometer to NMR at Low Temperatures,” J. Low Temp. Phys. 13, 607–615.
- Millar, J. M., A. M. Thayer, A. Bielecki, D. B. Zax, and A. Pines, 1985, “Zero Field NMR and NQR with Selective Pulses and Indirect Detection,” J. Chem. Phys. 83, 934–938.
- Moberly, L. A., and O. G. Symko, 1977, “Application of SQUID magnetometer to NMR thermometry,” IEEE Trans. Magn. 13, 358–360.
- Muck, M., C. Heiden, J. Clarke, 1994, “Investigation of Reduction of Excess Low Frequency Noise in RF SQUIDs,” J. Appl. Phys. 75, 4588–4592.
- Narasimhan, L. R., M. Takigawa, and M. B. Ketchen, 1994, “Magnetic Resonance of a Small Platinum Particle Using an Integrated DC SQUID,” Appl. Phys. Lett. 65, 1305–1307.
- Odehnal, M., 1986, “SQUID and nuclear magnetic resonance,” in Proceedings of the 4th Chech. Symposium on Weak Superconductivity (Electrotechnical Institute, Smolenice), pp. 31–39.
- Oja, A. S., A. J. Annila, and Y. Takano, 1991, “Investigation of Nuclear Magnetism in Silver Down to Picokelvin Temperatures, II,” J. Low Temp. Phys. 85, 1–24.
- Pake, G. E., 1948, J. Chem. Phys. 16, 327.
- Penny, R. D., D. Lathrop, B. D. Thorson, B. R. Whitecotton, R. H. Koch, and J. R. Rosen, 1997, “Wide Band Front End for High Frequency SQUID Electronics,” in ASC ’96: Proceedings of the Applied Superconducting Conference, 1996, Pittsburg, USA, IEEE Trans. Appl. Supercond. 7, 2323–2326.
- Pickens, K. S., D. I. Bolef, M. R. Holland, and R. K. Sundfors, 1984a, “Superconducting quantum interference device detection of acoustic NQR of and in antimony metals,” Phys. Rev. B 30, 3644–3648.
- Pickens, K. S., G. Mozurkevich, D. I. Bolef, and R. K. Sundfors, 1984b, “SQUID detection of acoustomagnetic effects: nuclear acoustic resonance in tantalum metal,” Phys. Rev. Lett. 52, 156–159.
- Ramsey, N. F., and R. V. Pound, 1951, “Nuclear Audiofrequency Spectroscopy by Resonant Heating of the Nuclear Spin System,” Phys. Rev. 81, 278–279.
- Redfield, A. G., 1963, “Pure Nuclear Electric Quadrupole Resonance in Impure Copper,” Phys. Rev. 130, 589–595.
- Rogers, C. T., and R. A. Buhrman, 1984, “Composition of noise in metal-insulator-metal tunnel junctions,” Phys. Rev. Lett. 53, 1272–1275.
- Ryhanen, T., H. Seppa, R. Ilmoniemi, and J. Knuutila, 1989, “SQUID Magnetometers for Low Frequency Applications,” J. Low Temp. Phys. 76, 287–386.
- Sager, R. E., R. L. Kleinberg, P. A. Warkentin, and J. C. Weatly, 1977, “Magnetic relaxation in Superfluid near critical temperature,” Phys. Rev. Lett. 39, 1343–1346.
- Sager, R. E., A. D. Hibbs, and S. Kumar, 1992, “Using SQUIDs for AC Measurements,” IEEE Trans. Magn. 28, 3072–3077.
- Savo, B., F. C. Wellstood, and J. Clarke, 1987, “Low Frequency Excess Noise in Josephson Tunnel Junctions,” Appl. Phys. Lett. 50, 1757–1759.
- Schirmer, R. E., 1971, The Nuclear Overhauser Effect (Academic, New York).
- Schmid, D., 1973, “Nuclear Magnetic Double Resonance-Principles and Applications in Solid-State Physics,” Springer Tracts in Modern Physics No. 68, pp. 1–75.
- Seton, H. C., D. M. Bussel, J. M. S. Hutchison, I. Nicholson, and D. J. Lurie, 1992, “DC SQUID based NMR detection from room temperature samples,” Phys. Med. Biol. 37, 2133–2138.
- Seton, H. C., D. M. Bussel, J. M. S. Hutchison, and D. J. Lurie, 1995a, “Use of DC SQUID to improve the signal to noise ratio of low field MRI system,” IEEE Trans. Appl. Supercond. 5, 3218–3221.
- Seton, H. C., D. M. Bussell, and J. M. S. Hutchison, 1995b, “A DC SQUID RF Amplifier used in Low Field MRI System,” in Proceedings of the 2nd European Conference on Applied Superconductivity, edited by D. Dew-Hughes (IOP, Bristol), pp. 1487–1490.
- Seton, H. C., D. M. Bussel, and J. M. S. Hutchison, 1995c, “A Liquid Helium Cooled RF Coil and SQUID Amplifier for MRI at 0.01 T,” Proc. Soc. Magn. Res. 2, 959.
- Seton, H. C., J. M. S. Hutchison, D. M. Bussel, 1997a, “A Tuned SQUID Amplifier for MRI Based on a DOIT Flux Locked Loop,” in ASC ’96: Proceedings of the Applied Superconducting Conference, 1996, Pittsburgh, Pennsylvania, IEEE Trans. Appl. Supercond. 7, 3213–3216.
- Seton, H. C., J. M. S. Hutchison, and D. M. Bussel, 1997b, “A 4.2-K Receiver Coil and SQUID Amplifier Used to Improve the SNR of Low Field Magnetic Resonance Images of the Human Arm,” Meas. Sci. Technol. 8, 198–207.
- Silver, A. H., and J. E. Zimmerman, 1967, “Multiple Quantum Resonance Spectroscopy Through Weakly Connected Superconductor,” Appl. Phys. Lett. 10, 142–145.
- Sleator, T., E. L. Hahn, C. Hilbert, and J. Clarke, 1985, “Nuclear spin noise,” Phys. Rev. Lett. 55, 1742–1745.
- Sleator, T., E. L. Hahn, M. B. Heaney, C. Hilbert, and J. Clarke, 1986, “Nuclear electric quadrupole induction of atomic polarization,” Phys. Rev. Lett. 57, 2756–2759.
- Sleator, T., E. L. Hahn, C. Hilbert, and J. Clarke, 1987, “Nuclear Spin Noise and Spontaneous Emission,” Phys. Rev. B 36, 1969–1980.
- Slichter, C. P., 1989, Principles of Magnetic Resonance, 3rd edition (Springer, New York).
- Solodovnikov, I. S., and N. V. Zavaritzkij, 1992, “Interaction of the liquid spins with the spins of nuclei at the wall,” Zh. Eksp. Teor. Fiz. Let. 56, 165–168 [JETP Lett. 56, 162–165].
- Stephenson, D., and J. A. S. Smith, 1988, “Nitrogen-14 Cross-Correlation Spectroscopy,” Proc. R. Soc. London, Ser. A 416, 149–178.
- Stephenson, D., and John A. S. Smith, 1995, “Zeeman Transitions in Low Magnetic Field: Dependence of Line Shapes on the Asymmetry Parameter for Spin Systems,” Z. Naturforsch. Teil A 51A, 348–352.
- Strombotne, R. L., and E. L. Hahn, 1964, “Longitudinal Nuclear Spin-Spin Relaxation,” Phys. Rev. 133, 1616–1629.
- Suzuki, H., Y. Higashino, and T. Ohtzuka, 1980, “SQUID NMR studies of ” J. Low Temp. Phys. 41, 449–461.
- Svistov, L. E., J. Löw, and H. Benner, 1993, “The effect of Nuclear Spin Waves on Magnetization of ” J. Phys.: Condens. Matter 5, 4215–4224.
- Tesche, C. D., and J. Clarke, 1977, “DC SQUID: Noise and Optimization,” J. Low Temp. Phys. 29, 301–331.
- Tesche, C. D., and J. Clarke, 1979, “DC SQUID: Current Noise,” J. Low Temp. Phys. 37, 397–403.
- Thomasson, S. L., and C. M. Gould, 1995a, “High Slew Rate Large Bandwidth Integrated DC SQUID Magnetometer for NMR Applications,” IEEE Trans. Appl. Supercond. 5, 3222–3225.
- Thomasson, S. L., and C. M. Gould, 1995b, “1 MHz Bandwidth True NMR SQUID Amplifier,” J. Low Temp. Phys. 101, 243–248.
- Thomasson, S. L., and C. M. Gould, 1996, “Direct Coupled DC SQUID Magnetometer for Ultralow Temperature NMR,” Czech. J. Phys. 46, Suppl S5, 2849–2850.
- Thompson, D. D., and R. S. J. Brown, 1961, “Low Field NMR of Coupled Spin- particle,” J. Chem. Phys. 35, 1984.
- Thompson, D. D., R. S. J. Brown, and M. Bloom, 1964, “Nuclear free precession in a very low magnetic field,” J. Chem. Phys. 40, 3076.
- TonThat, D. M., and John Clarke, 1996, “DC SQUID Spectrometer for Pulsed NMR and NQR at Frequencies up to 5 MHz,” Rev. Sci. Instrum. 67, 2890–2893.
- Van Duzer, T., and C. W. Turner, 1981, Principles of Superconductive Devices and Circuits (Elsevier/North-Holland, New York).
- Vlasenko, L. S., N. V. Zavaritzkij, and V. G. Fleisher, 1983, “Detection of optically polarized nuclei in semiconductors with the help of superconducting quantum interferometer,” Pis’ma Zh. Tekh. Fiz. 9, 1377–1381 [Sov. Tech. Phys. Lett. 9, 592 (1983)].
- Vlasenko, L. S., N. V. Zavaritzkij, S. V. Sorokin, and V. G. Fleisher, 1986, “Photonuclear magnetism of silicon in weak magnetic fields,” Zh. Eksp. Teor. Fiz. 91, 1496–1508 [Sov. Phys. JETP 64, 881–888 (1986)].
- Webb, R. A., 1977a, “Measurements of difference Between the Dynamic NMR and Static Susceptibility of Superfluid He-B using a RF SQUID,” Phys. Rev. Lett. 38, 1151–1155.
- Webb, R. A., 1977b, “New Technique for Improved Low Temperature SQUID NMR Experiments,” Rev. Sci. Instrum. 48, 1585–1594.
- Webb, R. A., 1977c, “Ferromagnetic Resonance Behavior in Superfluid ” Phys. Rev. Lett. 39, 1008–1011.
- Webb, R. A., 1978a, “Recent advances in SQUID NMR technique,” in Future Trends in Superconductive Electronics, AIP Conf. Proc. No. 44 (AIP, New York, 1978), pp. 49–57.
- Webb, R. A., 1978b, “NMR detection with the SQUID—Application to Liquid ” J. Phys. (Paris), Colloq. C6, 39, 1613–1617.
- Webb, R. A., 1978c, “Measurements of the Relaxation of the Longitudinal Magnetization in Superfluid ” J. Phys. (Paris) C6, 31–32.
- Weber, M. J., and E. L. Hahn, 1960, “Selective spin excitation and relaxation in Nuclear Quadrupole Resonance,” Phys. Rev. 120, 365–375.
- Weitenkamp, D. P., A. Bielecki, D. Zax, K. Zilm, and A. Pines, 1983, “Zero field NMR,” Phys. Rev. Lett. 50, 1807–1810.
- Wennberg, A. K. M., L. J. Friedman, and H. M. Bozler, 1984, “Pulsed NMR using DC SQUID,” in Proceedings of the 17th International Conference on Low Temperatures, edited by U. Eckern, A. Schmid, W. Weber, and H. Wuhl (Elsevier Science), Part I, pp. 265–266.
- Werner, U., B. Black, M. Ziegeweid, and A. Pines, 1993, “SQUID-NQR of Nitrogen-14 in Amino Acids and Small Peptides,” Chem. Phys. Lett. 209, 17–21.
- Wurm, M., J.-P. Brison, and J. Flouquet, 1996, “Low Temperature NMR measurements Using a DC SQUID,” Czech J. Phys. 46, Suppl. S5, pp. 2851–2852.
- Yesinowski, J. P., M. L. Buess, A. N. Garroway, M. Ziegeweid, and A. Pines, 1995, “Detection of and in Cocaine Base and Hydrochloride Using NQR, NMR, and SQUID Techniques,” Anal. Chem. 67, 2256–2263.
- Youngman, R. E., U. Werner-Zwanziger, and J. W. Zwanziger, 1995, “A Comparison of Strategies for Obtaining High Resolution NMR spectra for Quadrupole Nuclei,” Z. Naturforsch. Teil A 51A, 321–329.
- Zare, R. N., 1988, Angular Momentum (Wiley, New York).
- Zax, D. B., A. Bielecki, K. W. Zilm, and A. Pines, 1984a, “Heteronuclear Zero Field NMR,” Chem. Phys. Lett. 106, 550.
- Zax, D. B., A. Bielecki, A. Pines, and S. W. Sinton, 1984b, “Differentiation Between Nuclei in Alums by Fourier Transform Pure Nuclear Quadrupole Resonance,” Nature (London) 312, 351.
- Zax, D. B., A. Bielecki, K. W. Zilm, A. Pines, and D. P. Weitencamp, 1985, “Zero field NMR and NQR,” Chem. Phys. 83, 4877–4905.