• Accepted Paper

High-sensitivity vapor-cell quasi-dc atomic electric field sensor

Amy Damitz, George Burns, and Yuan-Yu Jau

Phys. Rev. Applied - Accepted 2 September, 2026

DOI: https://doi.org/10.1103/j38g-7bmf

Abstract

We report several technical approaches that significantly improve the performance of a vapor-cell atomic electrometer operating in the quasi-DC frequency domain ( 1 kHz). With a very small active volume of approximately 11 mm3 inside a 2$22cm^3$ vapor cell, we demonstrated a noise floor for electric field (E-field) sensitivity ranging from 0.2 to 7.7 (mV/m)/$\sqrt{\rm Hz}$ for a frequency band of 1–100 Hz. Our work utilizes only a bare vapor cell for electrometry, without any metal parts or electrodes, to ensure minimal distortion of the measured E-field and to minimize the effective sensing volume for high spatial resolution. The E-field-sensitive atomic state (Rydberg state) is excited and read out optically, maximizing the simplicity of the system design and enabling the miniaturization of quasi-DC E-field sensors for potential applications, such as diagnostics of electronics without physical contact, communications in and below the super-low frequency (SLF) band, proximity detection, remote activity surveillance, tracing charge signatures, and research in bioscience and geoscience.

Export citation

Export citation

Choose format for download:

Download Citation

If the author has provided any supplemental materials with this article they will be available upon publication of the version of record.

Sign In to Your Journals Account

Filter

Filter

Article Lookup

Enter a citation