- Open Access
Extracting edge radiation within a straight section of an electron storage ring
Phys. Rev. ST Accel. Beams 5, 020701 – Published 19 February, 2002
DOI: https://doi.org/10.1103/PhysRevSTAB.5.020701
Abstract
Edge radiation may be extracted within a straight section of an electron storage ring by using a tilted mirror with a hole (or slot) for passage of the electron beam and its velocity field. At wavelengths much greater than the critical wavelength of the ring’s synchrotron radiation, the flux distribution upon the mirror is almost independent of wavelength. When the reflected radiation is extracted through a nearby window, diffraction reduces the extracted flux at wavelengths exceeding times the hole radius. For the Aladdin 800 MeV electron storage ring, the extracted edge radiation may find application as a broadband source for wavelengths of or as a diagnostic of the bunch dimensions.
References (23)
- Yu. N. Dnestrovskii and D. P. Kostomarov, Sov. Phys. Dokl. 4, 132 (1959).
- Y. Shibata, S. Hasebe, K. Ishi, T. Takahashi, T. Ohsaka, M. Ikezawa, T. Nakazato, M. Oyamada, S. Urasawa, T. Yamakawa, and Y. Kondo, Phys. Rev. E 52, 6787 (1995).
- A. P. Potylitsyn, Nucl. Instrum. Methods Phys. Res., Sect. B 145, 169 (1998).
- M. Castellano, V. A. Verzilov, L. Catani, A. Cianchi, G. Orlandi, and M. Geitz, Phys. Rev. E 63, 056501 (2001).
- R. A. Bosch, Rev. Sci. Instrum. (to be published).
- Y.-L. Mathis, P. Roy, B. Tremblay, A. Nucara, S. Lupi, P. Calvani, and A. Gerschel, Phys. Rev. Lett. 80, 1220 (1998).
- P. Roy, Y.-L. Mathis, A. Paolone, P. Giura, A. Nucara, S. Lupi, P. Calvani, and A. Gerschel, Nuovo Cimento Soc. Ital. Fis. 20D, 415 (1998).
- P. Roy, M. Cestelli Guidi, A. Nucara, O. Marcouille, P. Calvani, P. Giura, A. Paolone, Y.-L. Mathis, and A. Gerschel, Phys. Rev. Lett. 84, 483 (2000).
- R. A. Bosch, Nucl. Instrum. Methods Phys. Res., Sect. A 454, 497 (2000).
- J. D. Jackson, Classical Electrodynamics (Wiley, New York,1975), 2nd ed.
- I. S. Gradshteyn and I. M. Ryzhik, Table of Integrals, Series, and Products (Academic Press, San Diego,1994), 5th ed., p. 517, Eq. 3.915.2.
- I. S. Gradshteyn and I. M. Ryzhik, Table of Integrals, Series, and Products (Ref. [[11]]), p. 697, Eq. 6.521.2.
- I. S. Gradshteyn and I. M. Ryzhik, Table of Integrals, Series, and Products (Ref. [[11]]), p. 759, Eqs. 6.686.5 and 6.686.6.
- R. A. Bosch and O. V. Chubar, in Synchrotron Radiation Instrumentation, E. Fontes, AIP Conf. Proc. No. 417 (AIP, New York,1997), p. 35.
- R. A. Bosch, Nucl. Instrum. Methods Phys. Res., Sect. A 431, 320 (1999).
- I. S. Gradshteyn and I. M. Ryzhik, Table of Integrals, Series, and Products (Ref. [[11]]), p. 697, Eqs. 6.521.2 and 6.521.4; p. 979, Eq. 8.473.1; p. 982, Eq. 8.486.17.
- X. Artru, M. Castellano, L. Catani, R. Chehab, D. Giove, K. Honkavaara, P. Patteri, M. Taurigna-Quere, A. Variola, and L. Wartski, Nucl. Instrum. Methods Phys. Res., Sect. A 410, 148 (1998).
- O. V. Chubar and N. V. Smolyakov, in Proceedings of the 1993 Particle Accelerator Conference, Washington, DC (IEEE, Piscataway, NJ,1993), p. 1626.
- R. A. Bosch, in Proceedings of the 1999 Particle Accelerator Conference, New York (IEEE, Piscataway, NJ,1999), p. 2397.
- U. Schade, A. Röseler, E. H. Korte, M. Scheer, and W. B. Peatman, Nucl. Instrum. Methods Phys. Res., Sect. A 455, 476 (2000).
- M. A. Green, D. L. Huber, E. M. Rowe, and B. Tonner, Rev. Sci. Instrum. 63, 1582 (1992).
- R. A. Bosch, Nucl. Instrum. Methods Phys. Res, Sect. A (to be published).
- T. E. May, R. A. Bosch, and R. L. Julian, in Proceedings of the 1999 Particle Accelerator Conference, New York (Ref. [[19]]), p. 2394.